A multi-purpose grinding attachment : a technical feasibility study / by Pedro B. Raña.

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Marikina, Metro Manila : Cavite State University-Main Campus, 1985.Description: xii, 113 pages : illustrations ; 28 cmContent type:
  • text
Media type:
  • unmediated
Carrier type:
  • volume
Subject(s): DDC classification:
  • 621.9 R15 1985
Online resources: Abstract: SAPANGHILA, ROBERTO P., Proposed Twelve (12) Storey School Building at St. Dominic Complex in Bacoor City, Cavite. Narrative Report. Master of Engineering major in Structural Engineering, Cavite State University, Indang Cavite. November 2014. Adviser: Engr. Marcelino A. Dagasdas Jr. The practicum project entitled “Proposed Twelve (12) Storey School Building at Saint Dominic Complex In Bacoor City, Cavite” was conducted to prepare a structural analysis and design of twelve (12) storey school building of Saint Dominic College of Asia including the site development plan. Basically this study focused on the design of building components and members like slabs, beams, columns, and footings. The project was started by gathering of information through a series of inspection, line measurement and securing of previous data adapted to existing buildings of Saint Dominic College of Asia. This practicum was conducted at Saint Dominic Complex, Talaba, Bacoor, Cavite from June 2014 to October 2014. The practicum activities followed four steps namely data gathering, development planning, architectural and structural planning including analysis and design results presentation. Data gathering consisted of securing the location map, the existing site development plan, the existing drainage system and traffic flow inside the complex. In order to come up with a new site development, a careful study was conducted and a serious interview with the owners was made for a possible location of the proposed building. The enrolment trend was reviewed to project the enrollees in every school calendar year to anticipate what building level should be completed for that certain school year, The main objective of this study was to structurally design a twelve storey school building projected to a ten year development plan. After the exact location had been determined, the architectural and structural plans were drafted carefully. The structural computation processes followed including the design. The building main components was analyzed using STAAD software and designed using the spreadsheet program. The design was tried first using concrete compressive strength of 33 Mpa and steel reinforcement yield strength of 414 Mpa. The design result of trial sections were found to be too large, hence a higher yield strength was considered. In this study, it was recommended to use a higher compressive strength of concrete like 33Mpa (6000 psi) or greater to all structural members so as to minimized building component’s section and will result in larger cross section. In construction, it was recommended to use the early strength additives for concrete to lessen the idle time of construction during curing. The use of Fibrocin fiber for slabs may lessen or avoid cracks during and after concrete curing.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Materials specified URL Status Notes Date due Barcode
Theses / Manuscripts Theses / Manuscripts Ladislao N. Diwa Memorial Library Theses Section Non-fiction 621.9 R15 1985 (Browse shelf(Opens below)) Link to resource Room use only T-5918 00009658

Thesis (Master of Technician Education) Marikina Institute of Science and Technology

Includes bibliographical references.


SAPANGHILA, ROBERTO P., Proposed Twelve (12) Storey School Building at St. Dominic Complex in Bacoor City, Cavite. Narrative Report. Master of Engineering major in Structural Engineering, Cavite State University, Indang Cavite. November 2014. Adviser: Engr. Marcelino A. Dagasdas Jr.

The practicum project entitled “Proposed Twelve (12) Storey School Building at Saint Dominic Complex In Bacoor City, Cavite” was conducted to prepare a structural analysis and design of twelve (12) storey school building of Saint Dominic College of Asia including the site development plan.

Basically this study focused on the design of building components and members like slabs, beams, columns, and footings.

The project was started by gathering of information through a series of inspection, line measurement and securing of previous data adapted to existing buildings of Saint Dominic College of Asia.

This practicum was conducted at Saint Dominic Complex, Talaba, Bacoor, Cavite from June 2014 to October 2014. The practicum activities followed four steps namely data gathering, development planning, architectural and structural planning including analysis and design results presentation.

Data gathering consisted of securing the location map, the existing site development plan, the existing drainage system and traffic flow inside the complex. In order to come up with a new site development, a careful study was conducted and a serious interview with the owners was made for a possible location of the proposed building.

The enrolment trend was reviewed to project the enrollees in every school calendar year to anticipate what building level should be completed for that certain school year,

The main objective of this study was to structurally design a twelve storey school building projected to a ten year development plan. After the exact location had been determined, the architectural and structural plans were drafted carefully. The structural computation processes followed including the design. The building main components was analyzed using STAAD software and designed using the spreadsheet program.

The design was tried first using concrete compressive strength of 33 Mpa and steel reinforcement yield strength of 414 Mpa. The design result of trial sections were found to be too large, hence a higher yield strength was considered.

In this study, it was recommended to use a higher compressive strength of concrete like 33Mpa (6000 psi) or greater to all structural members so as to minimized building component’s section and will result in larger cross section. In construction, it was recommended to use the early strength additives for concrete to lessen the idle time of construction during curing. The use of Fibrocin fiber for slabs may lessen or avoid cracks during and after concrete curing.