Investigation and improvement of sewerage system in Cavite State University (Phase II) / by Joemar M. Digma.

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Indang, Cavite : Cavite State University- Main Campus, 2000.Description: 94 pages : illustrations ; 28 cmContent type:
  • text
Media type:
  • unmediated
Carrier type:
  • volume
Subject(s): DDC classification:
  • 624.16 D56 2000
Online resources: Production credits:
  • College of Engineering, and Information Technology (CEIT)
Abstract: DIGMA, JOEMAR MARQUITA, "Investigation and Improvement of Sewerage in Cavite State University (Phase Il)" Design Project, Bachelor of Science in Civil Engineering, Cavite State University, Indang Cavite, March 2000. Adviser: Engr. Cene Bago. This design project was conducted in Cavite State University (Phase Il) to investigate the existing sewerage and drainage in Cavite State University; provide proper design and recommendation for the improvement of the sewerage system; give an appropriate recommendation to enhance sanitary condition of the university; and to provide the estimated cost of the proposed design. The design project covered approximately 1.35 hectares. The design involves a storm sewer and sanitary sewer. Stom sewer design, facilitate the Physical Science, the Engineering and the whole Animal Science Department Area including the animal farm Cross Drain was installed with a 300 mm diameter pipe to avoid overflow on the road pavement. Pipe varied from 300 to 900 mm diameter, which was computed using the Rational Method. Sanitary sewer lines were installed generally in the whole area. A diameter of 200 mm diameter was used for the main line. There was a treatment plant installed in the area for treating wastes especially those from laboratory rooms. Estimate provides the total cost for materials and cost of labor. An increase in total price was deserved in using ATLANTA SPIRAL pipes over concrete pipes.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Materials specified URL Status Notes Date due Barcode
Theses / Manuscripts Theses / Manuscripts Ladislao N. Diwa Memorial Library Theses Section Non-fiction 624.16 D56 2000 (Browse shelf(Opens below)) Link to resource Room use only DP-19 00000378

Design Project (BS Civil Engineering) Cavite State University.

Includes bibliographical references.

College of Engineering, and Information Technology (CEIT)

DIGMA, JOEMAR MARQUITA, "Investigation and Improvement of Sewerage in Cavite State University (Phase Il)" Design Project, Bachelor of Science in Civil Engineering, Cavite State University, Indang Cavite, March 2000. Adviser: Engr. Cene Bago.

This design project was conducted in Cavite State University (Phase Il) to investigate the existing sewerage and drainage in Cavite State University; provide proper design and recommendation for the improvement of the sewerage system; give an appropriate recommendation to enhance sanitary condition of the university; and to provide the estimated cost of the proposed design.
The design project covered approximately 1.35 hectares. The design involves a storm sewer and sanitary sewer. Stom sewer design, facilitate the Physical Science, the Engineering and the whole Animal Science Department Area including the animal farm Cross Drain was installed with a 300 mm diameter pipe to avoid overflow on the road pavement. Pipe varied from 300 to 900 mm diameter, which was computed using the Rational Method. Sanitary sewer lines were installed generally in the whole area. A diameter of 200 mm diameter was used for the main line. There was a treatment plant installed in the area for treating wastes especially those from laboratory rooms.
Estimate provides the total cost for materials and cost of labor. An increase in total price was deserved in using ATLANTA SPIRAL pipes over concrete pipes.

Submitted copy for the University Library 03-27-2000 DP-19

Copyright © 2023. Cavite State University | Koha 23.05