000 | 03223nam a2200373 a 4500 | ||
---|---|---|---|
003 | OSt | ||
005 | 20231009091942.0 | ||
008 | 181022s19uu xx 00 eng d | ||
040 | _cCvSU Main Campus Library | ||
041 | 0 | _aeng | |
082 | 0 | 4 |
_a333.910 _bD45 2017 |
100 | 0 |
_aDescartin, Hana Pearl A. _eauthor _924027 |
|
245 | 1 | 0 |
_aAssessment of the water supply in Silang, Cavite / _cby Hana A. Descartin and Jerome Ceguia A. Luceros. |
260 | 0 |
_aIndang, Cavite : _c2017. _bCavite State University- Main Campus, |
|
300 |
_axiii, 79 pages : _c28 cm. _billustrations ; |
||
336 |
_2rdacontent _atext |
||
337 |
_2rdamedia _aunmediated |
||
338 |
_2rdacarrier _avolume |
||
500 | _aThesis (Bachelor of Science in Agricultural Engineering) Cavite State University | ||
504 | _aIncludes bibliographical references. | ||
508 | _aCollege of Engineering and Information Technology (CEIT) | ||
520 | 3 | _aDESCARTIN, HANA PEARL A. and LUCEROS, JEROME CEGUIA A. Assessment of the Water Supply System in Silang, Cavite. Undergraduate Thesis. Bachelor of Science in Agricultural Engineering. Cavite State University, Indang, Cavite. May 2017. Adviser: Dr. Leyma L. Cero The study was conducted from October 2016 to March 2017. Specifically, it aimed to assess the functional elements of the water supply system, assess the present demand of water in the supply system, project the future water demand of the service area of the water supply system in the next 10 years, and determine the physical, chemical and bacteriological properties of the water supplied to the consumers. The water supply system of Silang has four functional elements, namely: source, storage, treatment and distribution. Groundwater and springs are the main source of water with a combined capacity of 1,276,543.58 cu m/ month or 42,551.45 cu m/day. Only the Lucsuhin and Batas Pump Station obtained their water from springs. Water flows directly to distribution pipes. In the year 2016, the entire service area has a total water demand of 24,616,079.23 L/day with over 34,396 residential and government and 1,405 commercial establishments connections. The present water supply is still sufficient for 2016 until 2024, but for the succeeding years it will not be enough to meet the demand of increasing population assuming that the discharge of the sources remains the same. The physical, chemical and biological water properties that are supplied in Silang, Cavite passed the limit requirements of the Philippine National Standards Drinking Water (PNSDW). | |
541 |
_cSubmitted copy to the University Library. _d09/20/2017 _eT-7122 |
||
650 | 0 |
_aWater quality management _96947 |
|
650 | 0 |
_aWater supply _xManagement _92309 |
|
650 | 0 |
_aWater resources development _97315 |
|
650 | 0 |
_aWater quality _95279 |
|
650 | 0 |
_aWater quality _xMeasurement. _95279 |
|
690 |
_91355 _aBachelor of Science in Agricultural Engineering |
||
700 |
_aLuceros, Jerome Ceguia A. _924028 _eauthor |
||
700 |
_aCero, Leyma L. _91607 _eadviser |
||
856 |
_yClick here to view thesis abstract and table of contents _uhttp://library.cvsu.edu.ph/cgi-bin/koha/opac-retrieve-file.pl?id=c5d61d86c9f70955e54fafb5855715c2 |
||
942 |
_2ddc _cMAN |
||
999 |
_c11667 _d11667 |