000 04371nam a2200349 4500
003 OSt
005 20220329164820.0
008 220219b |||||||| |||| 00| 0 eng d
040 _cCvSU Main Campus Library
041 0 _aeng
082 0 4 _a624.16
_bN73 2019
100 _918807
_aNonong, Wes Auson P.
_eauthor
245 1 0 _aProposed reinforced concrete design of a four storey hospital building in Barangay Galicia 3 at Mendez, Cavite /
_cby Wes Auson P. Nonong and Joshua Ryan D. Paez.
260 _aIndang, Cavite :
_bCavite State University- Main Campus,
_c2019.
300 _axviii, 271 pages :
_billustrations ;
_c28 cm.
336 _2rdacontent
_atext
337 _2rdamedia
_aunmediated
338 _2rdacarrier
_avolume
500 _aDesign Project (Bachelor of Science in Civil Engineering) Cavite State University.
504 _aIncludes bibliographical references.
508 _aCollege of Engineering and Information Technology (CEIT), Department of Civil Engineering
520 3 _aNONONG, AUSON WES P., and PAEZ, JOSHUA RYAN D. Proposed Reinforced Concrete Design of a Four Storey Hospital Building In Barangay Galicia 3 at Mendez, Cavite. Undergraduate Thesis. Bachelor of Science in Civil Engineering. Cavite State University, Indang, Cavite. June 2019. Adviser: Eng,r. Renato B. Cubilla. The design project entitled, "Proposed Reinforced Concrete Design of a Four Storey Hospital Building in Barangay Galicia 3 at Mendez, Cavite" was conducted from August 2018 to May 2019. The aim of the study was to provide a plan and proposed design for the hospital building that can be found in Mendez, Cavite and apply what the authors learned from their studies and experiences. The study included the computations of beams, columns, footings and slabs. This included the architectural plan, structural plan, electrical layout, plumbing layout and cost estimate of the proposed building. The total elevation was 12 meters with each floor having 3 meters in elevation. The floor area of the 4 storey building was 2196 m2, with each floor having different function for the convenience of the patients and employees. The structural layout and analysis of the plan was computed with the use of STAAD. From the STAAD analysis, four beams were designed, beam 1, beam 2, beam 3 and tie beam, having 350 x 500, 350x500, 300x350 and 350x500 mm respectively. The columns having sizes of 400x400mm and 450x450mm and the footing with a dimension of 3200x3200mm and 5500x2000mm. The authors used different software such as the Structural Aided Analysis and Design (STAAD) software, Computer Aided Drafting Device (CARD) and Sketchup. The design moment, ultimate shear and ultimate load were calculated with the use of STAAD. The total cost estimate of the project was 141, 420, 796.65 php with 16,099.82php per square meters. The authors followed the standards set by the NSCP and after various computations, it is concluded that the design was safe. It is recommended to integrate green building innovations for the improvement of the 4-storey hospital building and the usage of lightweight but high strength materials. The authors also recommend the upgrade of the 2nd level hospital into a 3rd level hospital to improve and add more facilities for the welfare of the people. The total cost estimate of the project was 141, 420, 796.65 php with 16,099.82php per square meters. The authors followed the standards set by the NSCP and after various computations, it is concluded that the design was safe. It is recommended to integrate green building innovations for the improvement of the 4-storey hospital building and the usage of lightweight but high strength materials. The authors also recommend the upgrade of the 2nd level hospital into a 3rd level hospital to improve and add more facilities for the welfare of the people.
541 _cSubmitted to the University Library
_d08/08/2019
_eDP-730
650 0 _9669
_aCivil engineering
650 0 _918808
_aInfirmary
650 0 _918809
_aConcrete design
690 _91678
_aBachelor of Science in Civil Engineering
700 _918810
_aPaez, Joshua Ryan D.
_eauthor
700 _92640
_aCubilla, Renato B.
_eadviser
856 _uhttp://library.cvsu.edu.ph/cgi-bin/koha/opac-retrieve-file.pl?id=34882f381168c9ef033d935ff5ae1834
_yClick here to view abstract and table of contents
942 _2ddc
_cMAN
999 _c37272