100 #0 - MAIN ENTRY--PERSONAL NAME |
Personal name |
Aguilar, Hermeson M. |
9 (RLIN) |
17422 |
Relator term |
author |
245 10 - TITLE STATEMENT |
Title |
Design and development of an amplified digital electronic stetho-sphyg (stethoscope - sphygmomanometer) / |
Statement of responsibility, etc. |
by Hermeson M. Aguilar and Michael Christian V. Noel. |
260 0# - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
Indang, Cavite, |
Date of publication, distribution, etc. |
2006. |
Name of publisher, distributor, etc. |
Cavite State University - Main Campus |
300 ## - PHYSICAL DESCRIPTION |
Extent |
xvii, 159 pages : |
Dimensions |
28 cm. |
Other physical details |
illustrations ; |
336 ## - CONTENT TYPE |
Source |
rdacontent |
Content type term |
text |
337 ## - MEDIA TYPE |
Source |
rdamedia |
Media type term |
umediated |
338 ## - CARRIER TYPE |
Source |
rdacarrier |
Carrier type term |
volume |
500 ## - GENERAL NOTE |
General note |
Design Project (BS Electronics and Communications Engineering) Cavite State University. |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Includes bibliographical references. |
508 ## - CREATION/PRODUCTION CREDITS NOTE |
College and Department |
College of Engineering and Information Technology (CEIT) |
520 3# - SUMMARY, ETC. |
Summary, etc. |
AGUILAR, HERMESON M., and NOEL MICHAEL CHRISTIAN V., Design and Development of an Amplified Digital Electronic Stetho-Sphyg (Stethoscope-Sphygmomanometer). Undergraduate Design Project. Bachelor of Science in Electronics and Communications Engineering. Cavite State University, Indang, Cavite. May 2006. Adviser: Eng. Edwin R. Arboleda. <br/>The Design and Development of an Amplified Digital Electronic Stetho-Sphyg was conducted at Brgy. Bancod 1 and Brgy. Calumpang Cerca, Indang, Cavite. The design project is designed for measuring heart rate and blood pressure, and for studying the heart conditions, respiratory conditions and bowel conditions. The design project was guided by the following objectives: to design and construct an electronic stethoscope circuit that can amplify the heartbeat, respiratory and bowel sounds; to design and construct a digital sphygmomanometer that will display the measured heart rate on a seven-segment TED display, and blood pressure level on LCD; to test and evaluate the device; and to determine the cost of the device. The design project was composed of electronic stethoscope and digital sphygmomanometer. The electronic stethoscope was designed to hear and study heartbeat sounds, respiratory sounds and bowel sounds. It was designed based on the existing circuit of microphone amplifiers. It employed with a low-pass filter in order to pass the low frequency body sounds, and to attenuate background noises. The digital sphygmomanometer is the significant part of the device. It is use for measuring blood pressure level and heart rate that will be displayed on an LCD and in a -digit LED display, respectively.<br/>Evaluation of the device took place-at- the -Infirmary of the Cavite. State University on March 03, 2006. The device was evaluated on its accuracy to measure blood pressure level and heart rate. Three medical staffs measured the blood pressure level and heart rate of the ten respondents twice using the conventional stethoscope and sphygmomanometer. The. proponents measured again the heart rate and blood pressure level of the ten respondents twice using the design project. Using the method Analysis of Variance, it was found out that the device measured the blood pressure level and heart rate inaccurately_ The proponents analyzed the factors that may have caused the device to measure inaccurately. Another evaluation was conducted at the DCEE building of the Cavite State University. Based on the analysis of the results of the second evaluation, the device can measure the blood pressure level and heart rate accurately.<br/> |
541 ## - IMMEDIATE SOURCE OF ACQUISITION NOTE |
Date of acquisition |
09/08/2006 |
Accession number |
DP-217 |
Method of acquisition |
Submitted to the University Library<br/> |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Engineering design |
General subdivision |
Design. |
9 (RLIN) |
892 |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM |
Topical term or geographic name entry element |
Amplifiers. |
9 (RLIN) |
17424 |
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) |
9 (RLIN) |
4922 |
Course or Program |
Bachelor of Science in Electronics and Communications Engineering |
700 ## - ADDED ENTRY--PERSONAL NAME |
Personal name |
Noel, Michael Christian V. |
9 (RLIN) |
17425 |
Relator term |
author |
700 ## - ADDED ENTRY--PERSONAL NAME |
Personal name |
Arboleda, Edwin R. |
9 (RLIN) |
4719 |
Relator term |
adviser |
856 ## - ELECTRONIC LOCATION AND ACCESS |
Link text |
Click here to view thesis abstract and table of contents |
Electronic File |
<a href="http://library.cvsu.edu.ph/cgi-bin/koha/opac-retrieve-file.pl?id=d687acf8ec05b576fa8a3bf803212db0">http://library.cvsu.edu.ph/cgi-bin/koha/opac-retrieve-file.pl?id=d687acf8ec05b576fa8a3bf803212db0</a> |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Dewey Decimal Classification |
Koha item type |
Theses / Manuscripts |