Water and porous materials as cooling media of non-freon air cooler / (Record no. 7136)

MARC details
000 -LEADER
fixed length control field 03652nam a2200325 a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20230301134720.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 071126s19uu xx 00 eng d
040 ## - CATALOGING SOURCE
Transcribing agency CvSU Main Campus Library
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 697.93
Item number C31 2007
100 #0 - MAIN ENTRY--PERSONAL NAME
Personal name Cayao, Christian Deus T.
9 (RLIN) 13276
Relator term author
245 10 - TITLE STATEMENT
Title Water and porous materials as cooling media of non-freon air cooler /
Statement of responsibility, etc. by Christian Dues T. Cayao, Jeg Alex P. Dimapilis.
260 0# - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Indang, Cavite :
Date of publication, distribution, etc. 2007.
Name of publisher, distributor, etc. Cavite State University- Main Campus,
300 ## - PHYSICAL DESCRIPTION
Extent xix, 72 pages :
Dimensions 28 cm.
Other physical details illustrations ;
336 ## - CONTENT TYPE
Source rdacontent
Content type term text
337 ## - MEDIA TYPE
Source rdamedia
Media type term unmediated
338 ## - CARRIER TYPE
Source rdacarrier
Carrier type term volume
500 ## - GENERAL NOTE
General note Research study (Applied Research IV - - Science Curriculum) Cavite State University.
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Includes bibliographical references.
508 ## - CREATION/PRODUCTION CREDITS NOTE
College and Department Science High School, College of Education (CED)
520 3# - SUMMARY, ETC.
Summary, etc. CAYAO, CHRISTIAN DEUS T. and DIMAPILIS, JEG ALEX P. Water and Porous Materials as Cooling Media of Non — Freon Air Cooler. Research Study. Science High School, College of Education. Cavite State University, Indang, Cavite. April 2007. Adviser: Engr. Neil T. Penalba.<br/>The study was conducted in one of the researcher's residences at 394 A. Mabini St. Indang, Cavite. It aimed to identify porous materials which can be used as substitute to Freon as cooling media; compare the cooling performance of the cooler using water and porous materials and air cooler using Freon; compare the electric consumption and manufacturing cost of air cooler using water and different porous materials and air cooler using Freon ; and determine the acceptability of non — Freon air cooler based on design and performance.<br/>The non- Freon air cooler was built. The framework of the air cooler was made using aluminum. The porous material container was built using wire mesh and the water container was attached to the bottom of the air cooler. The blower and exhaust fan were placed inside the air cooler and certain wirings were made. The air cooler was covered with aluminum sheets and the air cooler was tested. The different treatments used in the study were: Tl - commercial air cooler, T2 - water and wood shavings, T3 - water and coconut husk and T4 - water and jute sack fiber. The study proved that the developed non- Freon air cooler which used water and porous materials was an effective air cooler which has lower electric consumption and cheaper cost. However, its cooling performance is not as great as that of the commercial air cooler. It was also found that the porous materials can be used as cooling media and T3 - water and coconut husk, wasproven as the best cooling medium. In terms of acceptability of design and performance, the non — Freon air cooler was considered excellent, but it also showed that it may need some improvement in terms of cooling performance and cooling time. It is recommended to conduct studies on how to improve the performance of the air cooler; conduct further studies on the contamination of the porous materials; and identify the factors considered by professionals which were not considered by consumers.<br/>
541 ## - IMMEDIATE SOURCE OF ACQUISITION NOTE
Method of acquisition Submitted to the University Library
Date of acquisition 04-24-2007
Accession number RS-520
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Air conditioning
General subdivision Economic aspects
9 (RLIN) 12638
690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN)
9 (RLIN) 8100
Course or Program Applied Research
Major Science Curriculum
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Dimapilis, Jeg Alex P.
Relator term author
9 (RLIN) 13277
700 ## - ADDED ENTRY--PERSONAL NAME
Personal name Penalba, Neil T.
Relator term adviser
9 (RLIN) 17353
856 ## - ELECTRONIC LOCATION AND ACCESS
Electronic File <a href="http://library.cvsu.edu.ph/cgi-bin/koha/opac-retrieve-file.pl?id=6b098fbe0f64c98f49ffd707b4b20077">http://library.cvsu.edu.ph/cgi-bin/koha/opac-retrieve-file.pl?id=6b098fbe0f64c98f49ffd707b4b20077</a>
Link text Click here to view thesis abstract and table of contents
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Theses / Manuscripts
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Shelving location Date acquired Source of acquisition Coded location qualifier Inventory number Total Renewals Full call number Barcode Date last seen Uniform Resource Identifier Price effective from Koha item type Public note
    Dewey Decimal Classification   Room use only Non-fiction Ladislao N. Diwa Memorial Library Ladislao N. Diwa Memorial Library Theses Section 04/24/2007 Submitted copy to the University Library. RS 600 2007 697.93 C31 2007 00007135 08/04/2020 http://library.cvsu.edu.ph/cgi-bin/koha/opac-retrieve-file.pl?id=6b098fbe0f64c98f49ffd707b4b20077 08/04/2020 Theses / Manuscripts RS-520
Copyright © 2024. Cavite State University | Koha 23.05