Design and implementation of a video surveillance system through switched telephone line of the Information Technology building, Cavite State University (CvSU) Main Campus / by Rommel H. Dimapilis, Leizl A. Maranan, and Jenny Lou Q. Narvaez

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Indang, Cavite: Cavite State University- Main Campus, 2005.Description: xi, 90 pages: illustrations ; 28 cmContent type:
  • text
Media type:
  • unmediated
Carrier type:
  • volume
Subject(s): DDC classification:
  • 620.0042  D46 2005
Online resources: Production credits:
  • College of Engineering, and Information Technology (CEIT)
Abstract: DIMAPILIS, ROMMEL H., MARANAN, LEIZL A., NARVAEZ, JENNY LOU Q., and VILLANUEVA, WALLY N. Design and Implementation of Video Surveillance System through Switched Telephone Line. Undergraduate Design Project. Bachelor of Science in Electronics and Communication Engineering and Bachelor of Science in Computer Engineering. Cavite State University Indang, Cavite. October 2004. Adviser: Engr. Mary-Anne D. Costa. The objective of the study was conducted to design and implement a video surveillance system. Specifically, it aimed to install an alarm system in the Internet Laboratory and the Dean's Office at the Information Technology Building design and construct a Dual Tone Multi-Frequency (DTMF) decoder-controller circuit, construct a transmitter for sending the video signal to the monitoring station, design and construct a power supply capable of supplying the needed voltage by the system, test and evaluate the performance of Video Surveillance System through Switched Telephone Lines through pilot testing and conduct a cost-computation of the study. The design project was composed of DTMF decoder-controller circuit, RF transmitter circuit, Power supply circuit, Telephone circuit, Antenna and the software. The DTMF decoder-controller circuit controls the whole operation of the surveillance system. The RF transmitter circuit on the other hand performs the sending of video captured by the surveillance camera to the monitoring station. The Power Supply circuit was designed to fit the requirements used by the device to operate the system. The Telephone Circuit is for dialing and controlling the transmitter, camera and rotator. Rhombic Antenna was used with maximum range of 286 meters. The monitoring station was located at the office of Civil Security inside the Administration Building. It was composed of television as receiver to view the video signal from the remote station at the IT building. The device has an input power of 350 mW and a carrier frequency of 482 MI-lz and may be transmitted within a maximum range of 286 m from the transmitter.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Materials specified URL Status Notes Date due Barcode
Theses / Manuscripts Theses / Manuscripts Ladislao N. Diwa Memorial Library Theses Section Non-fiction 620.0042 D46 2005 (Browse shelf(Opens below)) Link to resource Room use only DP-144 00001218

Design Project (BS Electronics and Communication Engineering) Cavite State University.

Includes bibliographical references.

College of Engineering, and Information Technology (CEIT)

DIMAPILIS, ROMMEL H., MARANAN, LEIZL A., NARVAEZ, JENNY LOU Q., and VILLANUEVA, WALLY N. Design and Implementation of Video Surveillance System through Switched Telephone Line. Undergraduate Design Project. Bachelor of Science in Electronics and Communication Engineering and Bachelor of Science in Computer Engineering. Cavite State University Indang, Cavite. October 2004. Adviser: Engr. Mary-Anne D. Costa.
The objective of the study was conducted to design and implement a video surveillance system. Specifically, it aimed to install an alarm system in the Internet Laboratory and the Dean's Office at the Information Technology Building design and construct a Dual Tone Multi-Frequency (DTMF) decoder-controller circuit, construct a transmitter for sending the video signal to the monitoring station, design and construct a power supply capable of supplying the needed voltage by the system, test and evaluate the performance of Video Surveillance System through Switched Telephone Lines through pilot testing and conduct a cost-computation of the study. The design project was composed of DTMF decoder-controller circuit, RF transmitter circuit, Power supply circuit, Telephone circuit, Antenna and the software. The DTMF decoder-controller circuit controls the whole operation of the surveillance system. The RF transmitter circuit on the other hand performs the sending of video captured by the surveillance camera to the monitoring station. The Power Supply circuit was designed to fit the requirements used by the device to operate the system. The Telephone Circuit is for dialing and controlling the transmitter, camera and rotator. Rhombic Antenna was used with maximum range of 286 meters. The monitoring station was located at the office of Civil Security inside the Administration Building. It was composed of television as receiver to view the video signal from the remote station at the IT building. The device has an input power of 350 mW and a carrier frequency of 482 MI-lz and may be transmitted within a maximum range of 286 m from the transmitter.

03/30/2005 DP-144 Submitted to the University Library