Proposed four-storey reinforced concrete building for the College of Nursing at the Cavite State University main campus / by Ronesa B. Caringal and Sarina M. Vigal.
Material type: TextLanguage: English Publication details: Indang, Cavite, 2006. Cavite State University - Main CampusDescription: xvi, 273 pages : illustrations ; 28 cmContent type:- text
- unmediated
- volume
- 624.153 C19 2006
- College of Engineering and Information Technology (CEIT)
Item type | Current library | Collection | Call number | Materials specified | Status | Notes | Date due | Barcode |
---|---|---|---|---|---|---|---|---|
Theses / Manuscripts | Ladislao N. Diwa Memorial Library Theses Section | Non-fiction | 624.153 C19 2006 (Browse shelf(Opens below)) | Room use only | DP-196 | 00001269 |
Browsing Ladislao N. Diwa Memorial Library shelves, Shelving location: Theses Section, Collection: Non-fiction Close shelf browser (Hides shelf browser)
Design Project (BS Civil Engineering) Cavite State University.
Includes bibliographical references.
College of Engineering and Information Technology (CEIT)
CARINGAL, RONESA B., AND SARINA M. VIGAL.; Proposed Four-Storey Reinforced Concrete Building for the College of Nursing at the Cavite State University Main Campus. Undergraduate Design Project. Bachelor of Science in Civil Engineering. April 2006. Adviser: Engr. Marcelino A. Dagasdas Jr.
The Proposed Four-Storey Reinforced Concrete Building for the College of Nursing was designed from June of 2005 to March 2006 at the Department of Civil Engineering, College of Engineering and Information Technology, Cavite State University, Indang, Cavite. The objectives of study were to enhance and apply the author's knowledge in designing, planning and estimating building; and to design a four-storey reinforced concrete building which can serve as reference for the possible expansion of the facilities at the Cavite State University. The structural member was designed with the aid of computer software known as Structural Aided Analysis and Design (STAAD) to simplify the complex computation. The references such as National Structural Code of the Philippines (NSCP), Ultimate Strength Design (USD), Simplified Methods in Building Construction, and Simplified Construction on Estimate were used in the analysis of structural member. The design project included the architectural plan, structural plan, lighting lay-out and plumbing including water supply, sewage layout, cost estimate and scaled model of the building. The estimated total cost of the project was Php 29,010, 081.25.
05/17/2006 DP-196 Submitted to the University Library