Local cover image
Local cover image

A Proposed design of three level demountable steel structure as an emergency evacuation center inside basketball covered court in Barangay Molino III, Bacoor City, Cavite / by Jeffrey P. Bagnol and Johnson L. Parungao.

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Indang, Cavite : Cavite State University- Main Campus, 2022.Description: xvi, 157 pages : illustrations ; 28 cmContent type:
  • text
Media type:
  • unmediated
Carrier type:
  • volume
Subject(s): DDC classification:
  • 691 B14 2022
Online resources: Production credits:
  • College of Engineering and Information Technology (CEIT)
Abstract: BAGNOL, JEFFREY P. and PARUNGAO, JOHNSON L. A Proposed Design of Three Level Demountable Steel Structure as an Emergency Evacuation Center Inside Basketball Covered Court in Barangay Molino III, Bacoor City, Cavite. Undergraduate Design Project. Bachelor of Science in Civil Engineering. Cavite State University Indang, Cavite. June 2022. Adviser: Engr. Renato B. Cubilla. The study entitled "A Proposed Design of Three Level Demountable Steel Structure as an Emergency Evacuation Center Inside Basketball Covered Court in Barangay Molino III, Bacoor City, Cavite" Main Campus from September 2020 to June 2022. - The study aims to prepare a steel design of a three-storey demountable steel structure. It has a total floor area of 538 square meters. Its highest point from the lower ground floor is 7.104 meters. The architectural concepts and plans were provided by the researchers. The researchers also provided structural plans such as details of steel beam, and details of steel column, and cost estimates of the design project. The engineering software, STAAD Pro Connect Edition V22, was used in the analysis of structural framework and structural connections. The architectural plans including the floor plans and elevations. The structural design of the building was done following the guidelines set by the National Structural Code of the Philippines (NSCP 2015), ASEP Steel Handbook and AISC shapes database. Load and Resistance Factor Design (LRFD) was also used in designing steel members respectively. After the analysis and manual computations, the design will be proven safe, efficient, and economical. The estimated project cost of the three-storey demountable steel structure using steel design with total floor area of 538 square meter is Php 7,648,353.08.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Materials specified URL Status Notes Date due Barcode
Theses / Manuscripts Theses / Manuscripts Ladislao N. Diwa Memorial Library Theses Section Non-fiction 691 B14 2022 (Browse shelf(Opens below)) Link to resource Room use only DP-764 00081954

Design Project (Bachelor of Science in Civil Engineering) Cavite State University.

Includes bibliographical references.

College of Engineering and Information Technology (CEIT)

BAGNOL, JEFFREY P. and PARUNGAO, JOHNSON L. A Proposed Design of Three Level Demountable Steel Structure as an Emergency Evacuation Center Inside Basketball Covered Court in Barangay Molino III, Bacoor City, Cavite. Undergraduate Design Project. Bachelor of Science in Civil Engineering. Cavite State University Indang, Cavite. June 2022. Adviser: Engr. Renato B. Cubilla.

The study entitled "A Proposed Design of Three Level Demountable Steel Structure as an Emergency Evacuation Center Inside Basketball Covered Court in Barangay Molino III, Bacoor City, Cavite" Main Campus from September 2020 to June 2022. - The study aims to prepare a steel design of a three-storey demountable steel structure. It has a total floor area of 538 square meters. Its highest point from the lower ground floor is 7.104 meters. The architectural concepts and plans were provided by the researchers. The researchers also provided structural plans such as details of steel beam, and details of steel column, and cost estimates of the design project. The engineering software, STAAD Pro Connect Edition V22, was used in the analysis of structural framework and structural connections. The architectural plans including the floor plans and elevations. The structural design of the building was done following the guidelines set by the National Structural Code of the Philippines (NSCP 2015), ASEP Steel Handbook and AISC shapes database. Load and Resistance Factor Design (LRFD) was also used in designing steel members respectively. After the analysis and manual computations, the design will be proven safe, efficient, and economical. The estimated project cost of the three-storey demountable steel structure using steel design with total floor area of 538 square meter is Php 7,648,353.08.

Submitted to the University Library 07/04/2022 DP-764

Click on an image to view it in the image viewer

Local cover image
Copyright © 2023. Cavite State University | Koha 23.05