Design and development of an automated cocolisap sprinkler system / by Lowie Allen C. Oloroso.

By: Contributor(s): Material type: TextTextLanguage: English Publication details: Indang, Cavite : Cavite State University-Main Campus, 2015.Description: xii, 106 pages : illustrations ; 28 cmContent type:
  • text
Media type:
  • unmediated
Carrier type:
  • volume
Subject(s): DDC classification:
  • 620 Ol7 2015
Online resources: Production credits:
  • College of Engineering and Information Technology (CEIT)
Abstract: OLOROSO, LOWIE ALLEN C. Design and Development of an Automated Cocolisap Sprinkler System.Undergraduate Design Project. Bachelor of Science in Computer Engineering. Cavite State University, Indang, Cavite. April 2015, Adviser: Mrs. Florence M. Banasihan. The study, Design and development of an automated cocolisap sprinkler system was designed and constructed at Cavite State University Main Campus (Saka) from August 2014 to February 2015. This was tested and evaluated at the Cavite State University Main Campus (Saka) from February 24 to March 3, 2015. The design project was conducted to develop an automated coconut sprinkler system. Specifically, it aimed to design and develop a sprinkler system that is being controlled by a micro-controller based circuit. Develop an application using the Arduino Framework, and a pipeline system that houses the nozzle sprinkler heads. The sprinkler system starts its process using a push button. The mixer mixes the solution in a designated amount. After the mixing process, the system will then begin the sprinkling process to all target areas. The process will continue until the water reaches the two critical levels, the low level and the empty level. When the water level reaches the low level, the first buzzer alarm will sound, warning the user that the water in the container has been deported to a low level. The buzzer alarm sound will continue until the water level reaches the empty level. When the water level reaches the zero or empty level, this triggers the system to automatically turn off the system.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Materials specified URL Status Notes Date due Barcode
Theses / Manuscripts Theses / Manuscripts Ladislao N. Diwa Memorial Library Theses Section Non-fiction 620 Ol7 2015 (Browse shelf(Opens below)) Link to resource Room use only DP-420 00009772

Design Project (BS Computer Engineering) Cavite State University

Includes bibliographical references.

College of Engineering and Information Technology (CEIT)

OLOROSO, LOWIE ALLEN C. Design and Development of an Automated Cocolisap Sprinkler System.Undergraduate Design Project. Bachelor of Science in Computer Engineering. Cavite State University, Indang, Cavite. April 2015, Adviser: Mrs. Florence M. Banasihan.

The study, Design and development of an automated cocolisap sprinkler system was designed and constructed at Cavite State University Main Campus (Saka) from August 2014 to February 2015. This was tested and evaluated at the Cavite State University Main Campus (Saka) from February 24 to March 3, 2015.

The design project was conducted to develop an automated coconut sprinkler system. Specifically, it aimed to design and develop a sprinkler system that is being controlled by a micro-controller based circuit. Develop an application using the Arduino Framework, and a pipeline system that houses the nozzle sprinkler heads.

The sprinkler system starts its process using a push button. The mixer mixes the solution in a designated amount. After the mixing process, the system will then begin the sprinkling process to all target areas. The process will continue until the water reaches the two critical levels, the low level and the empty level. When the water level reaches the low level, the first buzzer alarm will sound, warning the user that the water in the container has been deported to a low level. The buzzer alarm sound will continue until the water level reaches the empty level. When the water level reaches the zero or empty level, this triggers the system to automatically turn off the system.

Submitted to the University Library 08/04/2020 DP-420

Copyright © 2023. Cavite State University | Koha 23.05